Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2018-07-18
|
Emphasis |
L: HINOISE
|
Case Closed |
2019-08-27
|
Related Activity
Type |
Referral |
Activity Nr |
1360558 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100110 F04 I |
Issuance Date |
2018-08-23 |
Abatement Due Date |
2018-09-19 |
Current Penalty |
3104.5 |
Initial Penalty |
5174.0 |
Final Order |
2018-09-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.110(f)(4)(i): The quantity of LP-Gas stored within a building exceeded 300 pounds: On or about July 18th, 2018, at the jobsite location 9730 NW 25th St. Doral, FL 33172 storage area, the employer had eleven liquid propane gas cylinders inside the building, which exceeded the allowed 300 pounds. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2018-08-23 |
Abatement Due Date |
2018-09-26 |
Current Penalty |
3104.4 |
Initial Penalty |
5174.0 |
Final Order |
2018-09-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): On or about July 18, 2018, at the jobsite location 9730 NW 25th St. Doral, FL 33172, the employer did not develop and implement a written hazard communication program for employees exposed to chemicals such as, but not limited to DT-2R Plate Developer Replenisher (containing Potassium Hydroxide with a pH 14), and MRC (containing Naphtha, Xylene, IPA, Acetone and Heptane). |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19101200 F06 II |
Issuance Date |
2018-08-23 |
Abatement Due Date |
2018-09-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-09-11 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical a) On or about July 18, 2018, at the jobsite location 9730 NW 25th St. Doral, FL 33172 in the prep department, the container of Plate Developer Replenisher DT2R (containing Potassium Hydroxide with a pH 14), was not labeled with the required information. b) On or about July 18, 2018, at the jobsite location 9730 NW 25th St. Doral, FL 33172 in the press department, the container of MRC (containing Naphtha, Xylene, IPA, Acetone and Heptane), was not labeled with the required information. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100151 C |
Issuance Date |
2018-08-23 |
Abatement Due Date |
2018-10-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-09-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: On or about July 18, 2018, at the jobsite location 9730 NW 25th ST. Doral, FL 33172 prep department, an employee would use a corrosive chemical known as DT2R Plate Replenisher (containing Potassium Hydroxide with a pH 14), without having an eye wash station readily available. |
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-07-18
|
Emphasis |
L: FORKLIFT, N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2019-09-11
|
Related Activity
Type |
Referral |
Activity Nr |
1360558 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100028 B03 II |
Issuance Date |
2018-08-23 |
Current Penalty |
2328.0 |
Initial Penalty |
3880.0 |
Final Order |
2018-09-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.28(b)(3)(ii): Each employee was not protected from tripping into or stepping into or through any hole that was less than 4 feet (1.2 m) above a lower level by covers or guardrail systems: On or about 7/5/2018, at the Press Department of Bellak Color Corporation, 9730 NW 25th St, Doral, FL. An employee was exposed to a fall hazard while working in close proximity of a floor hole that lacked a cover. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100147 C01 |
Issuance Date |
2018-08-23 |
Abatement Due Date |
2018-09-18 |
Current Penalty |
3104.4 |
Initial Penalty |
5174.0 |
Final Order |
2018-09-10 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: On or about 7/5/2018, at the Press and Bindery Departments of Bellak Color Corporation, 9730 NW 25th St, Doral, FL. The employer did not establish an energy control program, resulting in the exposure of employees to a caught by hazard while performing servicing activities such as, but not limited to; changing motors and/or pumps of a MBO, replacement of broken and/or missing parts of presses, cleaning and lubrication of bindery equipment, etc. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100178 L01 I |
Issuance Date |
2018-08-23 |
Current Penalty |
2328.0 |
Initial Penalty |
3880.0 |
Final Order |
2018-09-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about 7/5/2018, at the Press Department of Bellak Color Corporation, 9730 NW 25th St, Doral, FL. Employees were exposed to struck and caught by hazards while a powered industrial truck (i.e. Forklift, Nissan 50, No. KCH02A25PV) was operated without training and/or evaluation. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2018-08-23 |
Current Penalty |
1978.8 |
Initial Penalty |
3298.0 |
Final Order |
2018-09-10 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about 7/5/2018, at the Bindery department of Bellak Color Corporation, 9730 NW 25th St, Doral, FL. a. A guillotine cutter (i.e. Heidelberg, Model No. Not available) had its pedal unprotected against unintended operation, exposing employees being caught by the point of operation. b. Employees were exposed to a caught by hazard while walking and/or working in the proximity of a guillotine cutter (i.e. Heidelberg, Model No. Not available) that had rotating parts unguarded. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100304 G05 |
Issuance Date |
2018-08-23 |
Current Penalty |
3104.4 |
Initial Penalty |
5174.0 |
Final Order |
2018-09-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: On or about 7/5/2018, at the Bindery Department of Bellak Color Corporation, 9730 NW 25th St, Doral, FL. A microwave oven (i.e. Whirlpool, No Model Available) was not provided with a continuous path to ground, exposing employees to an electrical hazard. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100305 B01 I |
Issuance Date |
2018-08-23 |
Abatement Due Date |
2018-08-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-09-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed: On or about 7/5/2018, at the Bindery Department of Bellak Color Corporation, 9730 NW 25th St, Doral, FL. A toggle switch was installed within an electrical junction box that had an unused opening which was not covered, exposing employees to an electrical hazard. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100305 B02 I |
Issuance Date |
2018-08-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-09-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: On or about 7/5/2018, at the Press Department of Bellak Color Corporation, 9730 NW 25th St, Doral, FL. A toggle switch was installed within an electrical junction box that lacked a coverplate, exposing employees to an electrical hazard. |
|
|