Search icon

STEVENS AND LAYTON, INC. - Florida Company Profile

Company Details

Entity Name: STEVENS AND LAYTON, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

STEVENS AND LAYTON, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 17 Oct 1967 (58 years ago)
Document Number: 322086
FEI/EIN Number 591174602

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 11260 PALM BCH BLVD, SUITE 1, FT. MYERS, FL, 33905, US
Mail Address: 11260 PALM BCH BLVD, SUITE 1, FT. MYERS, FL, 33905, US
ZIP code: 33905
County: Lee
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
DEAN V K President 11260 PALM BEACH BLVD, FORT MYERS, FL, 33905
DEAN STEPHANIE Vice President 11260 PALM BEACH BLVD, FORT MYERS, FL, 33905
DEAN V. KEITH Director 11260 PALM BEACH BLVD, FORT MYERS, FL, 33905
DEAN STEPHANIE K Director 11260 PALM BEACH BLVD, FORT MYERS, FL, 33905
DEAN V. KEITH Agent 11260 Palm Beach Blvd, Fort Myers, FL, 33905

Events

Event Type Filed Date Value Description
REGISTERED AGENT ADDRESS CHANGED 2022-02-23 11260 Palm Beach Blvd, Fort Myers, FL 33905 -
REGISTERED AGENT NAME CHANGED 2006-01-24 DEAN, V. KEITH -
CHANGE OF PRINCIPAL ADDRESS 1997-01-29 11260 PALM BCH BLVD, SUITE 1, FT. MYERS, FL 33905 -
CHANGE OF MAILING ADDRESS 1997-01-29 11260 PALM BCH BLVD, SUITE 1, FT. MYERS, FL 33905 -

Documents

Name Date
ANNUAL REPORT 2025-02-03
ANNUAL REPORT 2024-02-09
ANNUAL REPORT 2023-03-01
ANNUAL REPORT 2022-02-23
ANNUAL REPORT 2021-01-18
ANNUAL REPORT 2020-01-15
ANNUAL REPORT 2019-02-08
ANNUAL REPORT 2018-01-17
ANNUAL REPORT 2017-01-19
ANNUAL REPORT 2016-01-29

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342601432 0418800 2017-08-30 INTERSECTION OF SR-80 AND COUNTY ROAD 833, MOORE HAVEN, FL, 33471
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2017-11-14
Emphasis N: TRENCH, P: TRENCH
Case Closed 2018-02-14

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260652 A01
Issuance Date 2017-11-20
Current Penalty 3803.0
Initial Penalty 6338.0
Final Order 2017-12-15
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). On or about August 30, 2017, at the intersection of SR 80 and County Road 833, North Side, the employer had not provided any type of cave-in protection for two employees that had been sent inside the excavation which was 7'6" in depth, 22' in length, and 18'6" in width, and class C soil, exposing the employee to an engulfment hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2017-11-20
Current Penalty 3803.0
Initial Penalty 6338.0
Final Order 2017-12-15
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: On or about August 30, 2017, at the intersection of SR 80 and County Road 833, North Side, the employer had not provided a ladder that extended 3' above the landing of the excavation which was 7'6" in depth, 22' in length, and 18'6" in width, and class C soil, exposing the employee to a fall/engulfment hazard.
341010908 0420600 2015-10-21 MIDWAY BLVD AND EDGEWATER DRIVE, PORT CHARLOTTE, FL, 33952
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2015-10-22
Emphasis P: TRENCH, N: TRENCH
Case Closed 2017-12-20

Related Activity

Type Inspection
Activity Nr 1101108
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260021 B02
Issuance Date 2016-04-18
Abatement Due Date 2016-05-05
Current Penalty 3185.0
Initial Penalty 4900.0
Contest Date 2016-05-04
Final Order 2017-02-20
Nr Instances 2
Nr Exposed 12
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a. At the site, employees were exposed to struck by hazards, in that, training and education was not provided relating to safety requirements for excavations, to include at a minimum, shoring and sloping requirements, the various types of soil classifications, placing and handling the spoil so that it did not present a hazard to employees, safe means of egress to and from an excavation, on or about 10/21/2015. b. At the site, employees were exposed to a struck-by hazard, in that, training and education was not provided relating to hazards such as, but not limited to, handling material while inside a trench by using the excavator bucket to lower material such as gravel over the employees, on or about 10/21/2015.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260651 C02
Issuance Date 2016-04-18
Current Penalty 0.0
Initial Penalty 3500.0
Contest Date 2016-05-04
Final Order 2017-02-20
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a. On Midway Blvd, at the south side of the intersection with Edgewater Drive, employees were exposed to a struck by hazard, in that, employees were required to walk 40 feet when entering and exiting an excavation 10 feet deep and 45 feet long, on or about 10/21/2015.
Citation ID 02001
Citaton Type Serious
Standard Cited 19260651 J02
Issuance Date 2016-04-18
Current Penalty 7000.0
Initial Penalty 36000.0
Contest Date 2016-05-04
Final Order 2017-02-20
Nr Instances 1
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. a. On Edgewater Drive west of the intersection with Midway Blvd, employees were exposed to a struck by hazard while installing a 10 inch sanitary sewer pipe and a 12 inch reclaim water pipe, in that, excavators were driven on top of the spoil which was placed right at the edge of the north excavation wall which was 10 feet deep and 250 feet long, on or about 10/21/2015.
Citation ID 02002
Citaton Type Willful
Standard Cited 19260652 A01
Issuance Date 2016-04-18
Current Penalty 17815.0
Initial Penalty 63000.0
Contest Date 2016-05-04
Final Order 2017-02-20
Nr Instances 2
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraphs (b) or (c) of this section: a. On Midway Blvd, at the south side of the intersection with Edgewater Drive, employees were exposed to a caught in hazard, in that, shoring or sloping was not used to protect employees when installing a 10 inch sanitary sewer pipe in an excavation with type "C" soil which was 10 feet deep, 45 feet long and 17 feet wide, on or about 10/21/2015. b. On Edgewater Drive west of the intersection with Midway Blvd, employees were exposed to a caught in hazard, in that, shoring or sloping was not used to protect employees when installing a 10 inch sanitary sewer pipe and a 12 inch reclaim water pipe in an excavation with type "C" soil which was 10 feet deep, 250 feet long and 15 feet wide, on or about 10/21/2015.
308759182 0420600 2005-04-04 HWY 41 NORTH AT CEDAR CREEK, BONITA SPRINGS, FL, 34135
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2005-04-04
Emphasis N: TRENCH
Case Closed 2005-07-08

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2005-06-17
Abatement Due Date 2005-06-22
Current Penalty 656.25
Initial Penalty 875.0
Nr Instances 1
Nr Exposed 4
Gravity 03
Citation ID 01002
Citaton Type Serious
Standard Cited 19260651 C02
Issuance Date 2005-06-17
Abatement Due Date 2005-06-22
Current Penalty 656.25
Initial Penalty 875.0
Nr Instances 1
Nr Exposed 3
Gravity 03
Citation ID 01003
Citaton Type Serious
Standard Cited 19260652 A01
Issuance Date 2005-06-17
Abatement Due Date 2005-06-23
Current Penalty 1875.0
Initial Penalty 2500.0
Nr Instances 1
Nr Exposed 3
Gravity 10

Date of last update: 02 Apr 2025

Sources: Florida Department of State