Search icon

CWI LOGISTICS, INC. - Florida Company Profile

Company Details

Entity Name: CWI LOGISTICS, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

CWI LOGISTICS, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 22 Jul 1966 (59 years ago)
Last Event: AMENDMENT
Event Date Filed: 10 May 2023 (2 years ago)
Document Number: 307404
FEI/EIN Number 591145652

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 100 Industrial Blvd, Winter Haven, FL, 33880, US
Mail Address: 100 Industrial Blvd, Winter Haven, FL, 33880, US
ZIP code: 33880
County: Polk
Place of Formation: FLORIDA

Legal Entity Identifier

LEI number Registered As Jurisdiction Of Formation General Category Entity Status Entity created at
254900LQPKFM802NP415 307404 US-FL GENERAL ACTIVE 1966-07-22

Addresses

Legal c/o CORPORATION SERVICE COMPANY, 1201 HAYS ST, TALLAHASSEE, US-FL, US, 32301
Headquarters 502 E BRIDGERS AVENUE, AUBURNDALE, US-FL, US, 33823

Registration details

Registration Date 2019-09-24
Last Update 2024-07-19
Status ISSUED
Next Renewal 2025-07-28
LEI Issuer 5493001KJTIIGC8Y1R12
Corroboration Level FULLY_CORROBORATED
Data Validated As 307404

form 5500

Plan Name Plan Year EIN/PN Received Sponsor Total number of participants
CWI RETIREMENT TRUST 2023 591145652 2024-06-19 CWI LOGISTICS INC. 174
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2017-01-01
Business code 493100
Sponsor’s telephone number 8639673239
Plan sponsor’s address 100 INDUSTRIAL BLVD, WINTER HAVEN, FL, 338801036

Signature of

Role Plan administrator
Date 2024-06-19
Name of individual signing DOUGLAS SANDVIG
Valid signature Filed with authorized/valid electronic signature

Key Officers & Management

Name Role Address
CORPORATION SERVICE COMPANY Agent -
BOSTICK R. M Director 100 Industrial Blvd, Winter Haven, FL, 33880
Straughn Richard E Director 255 Magnolia Ave, Winter Haven, FL, 33884
Sandvig Douglas C Treasurer 255 Magnolia Ave, Winter Haven, FL, 33884
Hurst John President 100 Industrial Blvd, Winter Haven, FL, 33880

Fictitious Names

Registration Number Fictitious Name Status Filed Date Expiration Date Cancellation Date Mailing Address
G19000111082 CWI LOGISTICS EXPIRED 2019-10-11 2024-12-31 - 100 INDUSTRIAL BLVD., WINTER HAVEN, FL, 33880
G04002700068 SUPER COOL COLD STORAGE EXPIRED 2004-01-02 2024-12-31 - 100 INDUSTRIAL BLVD., WINTER HAVEN, FL, 33880

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2025-01-08 100 Industrial Blvd, Winter Haven, FL 33880 -
CHANGE OF MAILING ADDRESS 2025-01-08 100 Industrial Blvd, Winter Haven, FL 33880 -
AMENDMENT 2023-05-10 - -
AMENDMENT 2022-11-30 - -
NAME CHANGE AMENDMENT 2022-01-27 CWI LOGISTICS, INC. -
AMENDMENT 2019-10-15 - -
REGISTERED AGENT ADDRESS CHANGED 2000-04-17 1201 HAYS ST, TALLAHASSEE, FL 32301 -
REGISTERED AGENT NAME CHANGED 2000-04-17 CORPORATION SERVICE COMPANY -
RESTATED ARTICLES 1993-06-22 - RESTATED ARTICLES OF MERGER FILED T O CORRECT ORIGINAL MERGER FILED 3/2 0/92
CORPORATE MERGER 1992-03-20 - CORPORATION WAS A MERGER RESULT. TOTAL NUMBER OF QUALIFIED CORPORATION(S) INVOLVED WAS 1. CORPORATE MERGER NUMBER 300000001503

Documents

Name Date
ANNUAL REPORT 2025-01-08
ANNUAL REPORT 2024-02-07
Amendment 2023-05-10
ANNUAL REPORT 2023-02-22
Amendment 2022-11-30
ANNUAL REPORT 2022-03-02
Name Change 2022-01-27
ANNUAL REPORT 2021-01-29
ANNUAL REPORT 2020-01-15
Amendment 2019-10-15

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347293052 0420600 2024-02-21 102 INDUSTRIAL BLVD, WINTER HAVEN, FL, 33880
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2024-02-21
Emphasis L: FORKLIFT
Case Closed 2024-03-20

Related Activity

Type Complaint
Activity Nr 2130203
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100036 D01
Issuance Date 2024-03-05
Current Penalty 6223.2
Initial Penalty 10372.0
Final Order 2024-03-19
Nr Instances 1
Nr Exposed 45
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: a) For room number 4 at the T6 refrigerated warehouse facility, on or about 02/21/2024, the employer exposed employees to egress hazards, in that, the room's exit door was frozen shut from the inside and unable to be opened without several attempts to jar it free from ice accumulation.
Citation ID 02001
Citaton Type Other
Standard Cited 19100178 A04
Issuance Date 2024-03-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-03-19
Nr Instances 1
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(a)(4):Modifications or additions which affect capacity and safe operation of powered industrial trucks were performed by the employer without the manufacturer's prior written approval, and capacity, operation, and maintenance instruction plates, tags or decals of the powered industrial truck were not changed accordingly: a) For the refrigerated warehouse facility T6, On or about 02/21/2024, the employer exposed employees to potential fall hazards, in that, a man-basket attachment was used with forklifts to elevate personnel, and the forklift manufacturer's approval had not been obtained to use the man-basket. Capacity/operation data plates were not updated to account for the man-basket attachment.
346310592 0420600 2022-10-28 420 PROGRESS RD, AUBURNDALE, FL, 33823
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2022-10-28
Case Closed 2022-11-07

Related Activity

Type Inspection
Activity Nr 1600582
Safety Yes
346005820 0420600 2022-06-08 420 PROGRESS ROAD, AUBURNDALE, FL, 33823
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2022-06-08
Emphasis L: FORKLIFT
Case Closed 2022-10-31

Related Activity

Type Complaint
Activity Nr 1900661
Safety Yes
Health Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100178 A06
Issuance Date 2022-07-25
Abatement Due Date 2022-09-14
Current Penalty 1047.0
Initial Penalty 7458.0
Final Order 2022-08-16
Nr Instances 5
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(a)(6):The employer did not ensure that all nameplates or markings were maintained in a legible condition: (a) At the site, on or about 6/8/2022, the employer did not ensure that the nameplates and markings on the Toyota model 8FBE2OU forklifts, serial numbers # 11753, 11773, 11781, 11759, and 11749, were maintained in a legible condition while they were in service.
Citation ID 02001
Citaton Type Other
Standard Cited 19100028 B01 I
Issuance Date 2022-07-25
Abatement Due Date 2022-09-14
Current Penalty 1047.0
Initial Penalty 1047.0
Final Order 2022-08-16
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.28(b)(1)(i):29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): (a) At the site, on or about 6/8/2022, the employer did not ensure that employees working on the loading dock that was 4 feet above the lower level were protected from fall hazards.

Date of last update: 02 Apr 2025

Sources: Florida Department of State