Search icon

ARCADE LITHOGRAPHING CORP - Florida Company Profile

Company Details

Entity Name: ARCADE LITHOGRAPHING CORP
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

ARCADE LITHOGRAPHING CORP is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 28 Sep 1964 (61 years ago)
Date of dissolution: 27 Sep 2013 (12 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2013 (12 years ago)
Document Number: 285370
FEI/EIN Number 591085653

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2108 WHITFIELD PARK LOOP, SARASOTA, FL, 34243
Mail Address: 2108 WHITFIELD PARK LOOP, SARASOTA, FL, 34243
ZIP code: 34243
County: Manatee
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
URBAN, STEPHEN J. Director 2108 WHITFIELD PARK LOOP, SARASOTA, FL, 34243
URBAN, STEPHEN J. Secretary 2108 WHITFIELD PARK LOOP, SARASOTA, FL, 34243
URBAN, CLARENCE R. Agent 2108 WHITFIELD PARK LOOP, SARASOTA, FL, 34243
URBAN GLORIA J Vice President 2108 WHITFIELD PARK LOOP, SARASOTA, FL, 34243
URBAN CLARENCE R Director 2108 WHITFIELD PARK LOOP, SARASOTA, FL, 34243
URBAN CLARENCE R President 2108 WHITFIELD PARK LOOP, SARASOTA, FL, 34243
URBAN GLORIA J Director 2108 WHITFIELD PARK LOOP, SARASOTA, FL, 34243
URBAN AARON P Treasurer 2108 WHITFIELD PARK LOOP, SARASOTA, FL, 34243

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2013-09-27 - -
REGISTERED AGENT ADDRESS CHANGED 2004-02-19 2108 WHITFIELD PARK LOOP, SARASOTA, FL 34243 -
CHANGE OF PRINCIPAL ADDRESS 1988-02-18 2108 WHITFIELD PARK LOOP, SARASOTA, FL 34243 -
CHANGE OF MAILING ADDRESS 1988-02-18 2108 WHITFIELD PARK LOOP, SARASOTA, FL 34243 -
REGISTERED AGENT NAME CHANGED 1986-03-13 URBAN, CLARENCE R. -

Documents

Name Date
ANNUAL REPORT 2012-03-19
ANNUAL REPORT 2011-04-13
ANNUAL REPORT 2010-02-16
ANNUAL REPORT 2009-03-10
ANNUAL REPORT 2008-01-31
ANNUAL REPORT 2007-01-04
ANNUAL REPORT 2006-03-01
ANNUAL REPORT 2005-03-11
ANNUAL REPORT 2004-02-19
ANNUAL REPORT 2003-02-21

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
334876786 0420600 2012-06-27 2108 WHITEFIELD PARK LOOP, SARASOTA, FL, 34243
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2012-06-27
Emphasis N: AMPUTATE
Case Closed 2013-05-10

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2012-07-31
Abatement Due Date 2012-09-12
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2012-08-23
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that PVC plastic was used to distribute compressed air throughout inside the print shop to equipment such as the Miller Perfector printing press: a) On or about 6/27/12 employees working near the Miller Perfector printing press were exposed to being struck-by shards of PVC plastic if the pipes explode. The piping was used to deliver compressed air @ 110psi to equipment such as the Miller Perfector printing press. The PVC pipe was interconnected to air compressors such as a Speedaire. Among other methods, feasible and acceptable abatement methods to correct this hazardd are: 1. To replace the pipe with an approved ABS plastic 2. To encase the PVC pipe within shatter resistant materials 3. To use compressed air hoses
Citation ID 01002
Citaton Type Serious
Standard Cited 19100037 B06
Issuance Date 2012-07-31
Abatement Due Date 2012-08-21
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2012-08-23
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color: a) On or about 6/27/12 throughout the press shop exit signs were not illuminated or self-luminous. Paper copies of exit signs were used to designate exits.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100147 C01
Issuance Date 2012-07-31
Abatement Due Date 2012-09-12
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2012-08-23
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) On or about 6/27/12 at 2108 Whitfield Park Loop, Sarasota, FL the employer did not establish a written lockout tagout program for tasks such as but not limited to changing printing press rollers, cleaning grippers, and greasing fittings of equipment such as the Miller Perfector, Roland Favor It, and Bestech 40.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2012-07-31
Abatement Due Date 2012-08-14
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2012-08-23
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about 6/27/12 in the print shop guards were not installed on the Hamada printing press. b) On or about 6/27/12 in the binding room guards were not installed on the MBO B26-C binding machine.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19100219 D01
Issuance Date 2012-07-31
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2012-08-23
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) On or about 6/27/12 in the air compressor room the pulley of the Speedaire air compressor was not guarded.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19100219 E01 I
Issuance Date 2012-07-31
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-08-23
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: a) On or about 6/27/12 in the air compressor room the belt drive of the Speedaire air compressor was not guarded.
Citation ID 02001
Citaton Type Other
Standard Cited 19100303 G01 II
Issuance Date 2012-07-31
Abatement Due Date 2012-08-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-08-23
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a) On or about 6/27/12 on the west side of the print shop electrical panels such as, but not limited to, the electrical panel for the Bestech 40 were blocked by materials and equipment such as stacks of paper and dollies.

Date of last update: 01 Apr 2025

Sources: Florida Department of State