Search icon

B & A MANUFACTURING CO. - Florida Company Profile

Company Details

Entity Name: B & A MANUFACTURING CO.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

B & A MANUFACTURING CO. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 13 Apr 1950 (75 years ago)
Date of dissolution: 27 Sep 2024 (7 months ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2024 (7 months ago)
Document Number: 161169
FEI/EIN Number 590620173

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3665 E INDUSTRIAL WAY, RIVIERA BCH, FL, 33404
Mail Address: 3665 E INDUSTRIAL WAY, RIVIERA BCH, FL, 33404
ZIP code: 33404
County: Palm Beach
Place of Formation: FLORIDA

Commercial and government entity program

CAGE number Status Type Established CAGE Update Date CAGE Expiration SAM Expiration
26400 Obsolete U.S./Canada Manufacturer 1974-10-25 2022-06-10 2022-06-09 -

Contact Information

POC NORMAN H SCHMOTZER
Phone +1 561-848-8648
Fax +1 561-848-8621
Address 3665 E INDUSTRIAL WAY, WEST PALM BEACH, FL, 33404 3401, UNITED STATES

Ownership of Offeror Information

Highest Level Owner Information not Available
Immediate Level Owner Information not Available
List of Offerors (0) Information not Available

Key Officers & Management

Name Role Address
SCHMOTZER CAROLYN S ESTA 3665 E INDUSTRIAL WAY, WEST PALM BEACH, FL, 334043401
SCHMOTZER, CAROLYN S. Agent 3665 E INDUSTRIAL WAY, RIVIERA BEACH, FL, 33404

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2024-09-27 - -
REGISTERED AGENT NAME CHANGED 2022-03-31 SCHMOTZER, CAROLYN S. -
CHANGE OF PRINCIPAL ADDRESS 2009-04-22 3665 E INDUSTRIAL WAY, RIVIERA BCH, FL 33404 -
CHANGE OF MAILING ADDRESS 2009-04-22 3665 E INDUSTRIAL WAY, RIVIERA BCH, FL 33404 -
REGISTERED AGENT ADDRESS CHANGED 1983-04-19 3665 E INDUSTRIAL WAY, RIVIERA BEACH, FL 33404 -
NAME CHANGE AMENDMENT 1976-12-16 B & A MANUFACTURING CO. -

Documents

Name Date
ANNUAL REPORT 2023-01-10
AMENDED ANNUAL REPORT 2022-03-31
ANNUAL REPORT 2022-03-14
ANNUAL REPORT 2021-01-07
ANNUAL REPORT 2020-01-03
ANNUAL REPORT 2019-01-14
ANNUAL REPORT 2018-01-04
ANNUAL REPORT 2017-01-27
ANNUAL REPORT 2016-01-29
ANNUAL REPORT 2015-02-18

USAspending Awards. Contracts

Contract Type Award or IDV Flag PIID Start Date Current End Date Potential End Date
PO AWARD N0040612P4566 2012-08-02 2012-08-21 2012-08-21
Unique Award Key CONT_AWD_N0040612P4566_9700_-NONE-_-NONE-
Awarding Agency Department of Defense
Link View Page

Description

Title BIT SET, MASONRY DRILL
NAICS Code 333515: CUTTING TOOL AND MACHINE TOOL ACCESSORY MANUFACTURING
Product and Service Codes 5133: DRILL BITS, COUNTERBORES, AND COUNTERSINKS: HAND AND MACHINE

Recipient Details

Recipient B & A MANUFACTURING CO.
UEI L13RSY2FC4C5
Legacy DUNS 004132445
Recipient Address 3665 E INDUSTRIAL WAY, WEST PALM BEACH, 334043401, UNITED STATES

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343539243 0418800 2018-10-09 3665 E INDUSTRIAL WAY, RIVIERA BEACH, FL, 33404
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2018-10-26
Case Closed 2024-07-12

Related Activity

Type Complaint
Activity Nr 1387497
Safety Yes
Health Yes
Type Referral
Activity Nr 1396387
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100036 D01
Issuance Date 2019-04-09
Abatement Due Date 2019-05-03
Current Penalty 9282.0
Initial Penalty 9282.0
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 40
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: On or about October 10, 2018, at 3665 E Industrial Way, Riviera Beach, FL 33404, the employer allowed its employees to work at a jobsite where all designated Exit doors had locks and/or were obstructed by drop-in door security wooden bars. Employees can possibly be trapped and exposed to smoke inhalation, burns and possible death.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100132 E
Issuance Date 2019-04-09
Abatement Due Date 2019-05-03
Current Penalty 6630.0
Initial Penalty 6630.0
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(e): Defective and damaged equipment. Defective or damaged personal protective equipment shall not be used. On or about October 10, 2018, jobsite located at 3665 E Industrial Way, Riviera Beach, FL 33404, where an employee was exposed to injurious corrosives such as Black-Magic RT-S20 (a corrosive, with a pH of 1.9), the employer did not ensure that the employees defective personal protective equipment was in working order and allowed the employee to wear damaged gloves that had holes and/or rips exposing employee to chemical burns.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100133 A03
Issuance Date 2019-04-09
Abatement Due Date 2019-05-03
Current Penalty 6630.0
Initial Penalty 6630.0
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.133(a)(3): The employer shall ensure that each affected employee who wears prescription lenses while engaged in operations that involve eye hazards wears eye protection that incorporates the prescription in its design, or wears eye protection that can be worn over the prescription lenses without disturbing the proper position of the prescription lenses or the protective lenses. On or about October 26, 2018, jobsite located at 3665 E Industrial Way, Riviera Beach, FL 33404, the employer did not ensure that each affected employee who wore prescription lenses while operating the bench grinders wore eye protection that incorporated the prescription in its design, or wore eye protection that could be worn over the prescription lenses without disturbing the proper position of the prescription lenses or the protective lenses, exposing employees to flying projectiles.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19100134 C01
Issuance Date 2019-04-09
Abatement Due Date 2019-05-03
Current Penalty 3978.0
Initial Penalty 3978.0
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: On or about October 25, 2018, jobsite located at 3665 E Industrial Way, Riviera Beach, FL 33404, the employer did not have a written respiratory protection program for employees required to wear 3M 6200 Reusable Half Face Mask Respirators in the workplace, while performing spray painting and/or sandblasting operations, where the sandblasting operator was exposed to 91 milligrams per cubic meter of Particulates Not Otherwise Regulated (Total Dust), which is 6.057 times the PEL of 15 milligrams per cubic meter.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2019-04-09
Abatement Due Date 2019-05-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator. On or about October 25, 2018, jobsite located at 3665 E Industrial Way, Riviera Beach, FL 33404, the employer did not provide medical evaluations prior to requiring employees to wear 3M 6200 Reusable Half Face Mask Respirators in the workplace, while performing spray painting and/or abrasive blasting operations, where the sandblasting operator was exposed to 91 milligrams per cubic meter of Particulates Not Otherwise Regulated (Total Dust), which is 6.057 times the PEL of 15 milligrams per cubic meter.
Citation ID 01004C
Citaton Type Serious
Standard Cited 19100134 F01
Issuance Date 2019-04-09
Abatement Due Date 2019-05-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(1): The employer shall ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph. On or about October 25, 2018, at 3665 E Industrial Way, Riviera Beach, FL 33404, the employer did not ensure fit testing was conducted for employees required to wear 3M 6200 Reusable Half Face Mask Respirators in the workplace, while performing spray painting and/or abrasive blasting operations, where the sandblasting operator was exposed to 91 milligrams per cubic meter of Particulates Not Otherwise Regulated (Total Dust), which is 6.057 times the PEL of 15 milligrams per cubic meter.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100138 A
Issuance Date 2019-04-09
Current Penalty 5304.0
Initial Penalty 5304.0
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.138(a): The employer did not select and require employees to use appropriate hand protection when employees hands were exposed to hazardous condition(s): On or about October 26, 2018, jobsite located at 3665 E Industrial Way, Riviera Beach, FL 33404, the employer did not select, require and/or enforced the use of appropriate hand protection such as, punctured-resistant gloves or chemical impervious gloves for employees who were required to clean up sharp metal shavings and/or performing milling operations, exposing employees to puncture/lacerations wounds, and skin irritation/burn from chemical contact/splash.
Citation ID 01006
Citaton Type Serious
Standard Cited 19100141 G02
Issuance Date 2019-04-09
Abatement Due Date 2019-05-03
Current Penalty 9282.0
Initial Penalty 9282.0
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 40
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.141(g)(2): Eating and drinking areas. No employee shall be allowed to consume food or beverages in a toilet room nor in any area exposed to a toxic material. On or about October 10, 2018, jobsite located at 3665 E Industrial Way, Riviera Beach, FL 33404, the employer allowed employees to consume food and/or beverage in the employee break/lunch room area, which are exposed to Cadmium dust while eating on tables and using a black microwave whose surface was contaminated with hazardous chemical such as, but not limited to, Cadmium concentrations of 1.856 micrograms for wipe samples collected in this area.
Citation ID 01007
Citaton Type Serious
Standard Cited 19100151 C
Issuance Date 2019-04-09
Abatement Due Date 2019-05-03
Current Penalty 6630.0
Initial Penalty 6630.0
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: On or about October 26, 2018, jobsite located at 3665 E Industrial Way, Riviera Beach, FL 33404, the employer did not provide suitable facilities for quick drenching or flushing of the eyes and body were readily available in the work area for immediate use to employees who were required to work with hazardous chemicals, such as, but not limited to, Black-Magic RT-S20 (corrosive, pH of 1.9), and Sta Clear Muriatic Acid (corrosive, pH 1.16), while performing cleaning and/or metal prepping operations.
Citation ID 01008A
Citaton Type Serious
Standard Cited 19100215 A02
Issuance Date 2019-04-09
Abatement Due Date 2019-05-03
Current Penalty 7956.0
Initial Penalty 7956.0
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(a)(2): Guard design. The safety guard shall cover the spindle end, nut, and flange projections. The safety guard shall be mounted so as to maintain proper alignment with the wheel, and the strength of the fastenings shall exceed the strength of the guard: On or about October 10, 2018, jobsite located at 3665 E Industrial Way, Riviera Beach, FL 33404, employees were exposed to struck by hazards when the employer did not ensure that the abrasive wheel(s) used on grinding machinery in the Grinding area were provided with safety guard(s) which covered the spindle end, nut, and flange projections.
Citation ID 01008B
Citaton Type Serious
Standard Cited 19100215 A04
Issuance Date 2019-04-09
Abatement Due Date 2019-05-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: a. On or about October 9, 2018, jobsite located at 3665 E Industrial Way, Riviera Beach, FL 33404, employees were exposed to struck by hazards when the employer did not ensure that work rest were installed on grinding machinery in the Manual Milling area. b. On or about October 9, 2018, jobsite located at 3665 E Industrial Way, Riviera Beach, FL 33404, employees were exposed to struck by hazards when the employer did not ensure that work rest were installed on grinding machinery in the Grinding area.
Citation ID 01008C
Citaton Type Serious
Standard Cited 19100215 B09
Issuance Date 2019-04-09
Abatement Due Date 2019-05-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: a. On or about October 9, 2018, jobsite located at 3665 E Industrial Way, Riviera Beach, FL 33404, employees were exposed to struck by hazards when the employer did not ensure that a tongue guard was installed on grinding machinery in the Manual Milling area. b. On or about October 9, 2018, jobsite located at 3665 E Industrial Way, Riviera Beach, FL 33404, employees were exposed to struck by hazards when the employer did not ensure that a tongue guard was installed on grinding machinery in the Grinding area.
Citation ID 01009A
Citaton Type Serious
Standard Cited 19101000 A02
Issuance Date 2019-04-09
Abatement Due Date 2019-05-03
Current Penalty 3978.0
Initial Penalty 3978.0
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of Particulates Not Otherwise Regulated (Total Dust) listed in Table Z-1 in excess of the 8 hour Time Weighted Average concentration of 15 mg/m^3: On or about October 25, 2018, jobsite located at 3665 E Industrial Way, Riviera Beach, FL 33404, the employer did not ensure employees were protected from respiratory hazards in excess of the permissible exposure limit (PEL), an employee while performing sandblasting operations was exposed to 91 milligrams per cubic meter of Particulates Not Otherwise Regulated (Total Dust), which is 6.057 times the PEL of 15 milligrams per cubic meter.
Citation ID 01009B
Citaton Type Serious
Standard Cited 19101000 E
Issuance Date 2019-04-09
Abatement Due Date 2019-06-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): On or about October 25, 2018, jobsite located at 3665 E Industrial Way, Riviera Beach, FL 33404, the employer failed to implement feasible administrative or engineering controls to achieve compliance below the PEL, where an employee performing sandblasting operations was overexposed to Particulates Not Otherwise Regulated (Total Dust).
Citation ID 01010A
Citaton Type Serious
Standard Cited 19101027 D01 I
Issuance Date 2019-04-09
Abatement Due Date 2019-05-03
Current Penalty 9282.0
Initial Penalty 9282.0
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1027(d)(1)(i): Each employer who has a workplace or work operation covered by this section shall determine if any employee may be exposed to cadmium at or above the action level: On or about October 10, 2018, at 3665 E Industrial Way, Riviera Beach, FL 33404, employees were performing welding, flux tipping and milling operations using metal pieces and working on surfaces which contain Cadmium, and the employer did not perform exposure monitoring to assess hazards and Cadmium exposure associated with these operations.
Citation ID 01010B
Citaton Type Serious
Standard Cited 19101027 K01
Issuance Date 2019-04-09
Abatement Due Date 2019-05-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1027(k)(l): All surfaces shall be maintained as free as practicable of accumulations of cadmium. On or about October 10, 2018, jobsite located at 3665 E Industrial Way, Riviera Beach, FL 33404, the employer did not maintain surfaces free of accumulation of Cadmium, exposing employees to Cadmium contaminated surfaces while performing welding and flux tipping operations.
Citation ID 01010C
Citaton Type Serious
Standard Cited 19101027 M04 I
Issuance Date 2019-04-09
Abatement Due Date 2019-05-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1027(m)(4)(i): The employer did not institute a training program for all employees who are potentially exposed to cadmium, assure employee participation in the program, and maintain a record of the contents of such program: On or about October 10, 2018, jobsite located at 3665 E Industrial Way, Riviera Beach, FL 33404, the employer did not institute a training program for employees who were exposed to cadmium, did not assure employees participate in a training program, nor maintained a record of the training program, while laboratory results indicated cadmium concentrations ranging from 1.3894 to 2076.6 micrograms from wipe samples collected at the welders' workstations.
Citation ID 01011A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2019-04-09
Abatement Due Date 2019-05-03
Current Penalty 9282.0
Initial Penalty 9282.0
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 40
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about October 10, 2018, jobsite located at 3665 E Industrial Way, Riviera Beach, FL 33404, the employer did not develop and implement a written hazard communication program for employees who were required to work with hazardous chemicals, such as, but not limited to, Black-Magic RT-S20 (corrosive, pH of 1.9), Sta Clear Muriatic Acid (corrosive, pH 1.16), Iron Oxide Fumes, Manganese Fumes, Vanadium Fumes, Cobalt Dust & Fumes, Zinc Oxide Fumes, Copper Fumes and Chromium.
Citation ID 01011B
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2019-04-09
Abatement Due Date 2019-05-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 40
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: On or about October 10, 2018, at 3665 E Industrial Way, Riviera Beach, FL 33404, the employer did not provide effective information and training for employees who were required to work with hazardous chemicals, such as, but not limited to, Black-Magic RT-S20 (corrosive, pH of 1.9), Sta Clear Muriatic Acid (corrosive, pH 1.16), Iron Oxide Fumes, Manganese Fumes, Vanadium Fumes, Cobalt Dust & Fumes, Zinc Oxide Fumes, Copper Fumes and Chromium.
Citation ID 02001
Citaton Type Other
Standard Cited 19040029 A
Issuance Date 2019-04-09
Abatement Due Date 2019-05-03
Current Penalty 1327.0
Initial Penalty 1327.0
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 40
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.29(a): Basic requirement. You must use OSHA 300, 300-A, and 301 forms, or equivalent forms, for recordable injuries and illnesses. The OSHA 300 form is called the Log of Work-Related Injuries and Illnesses, the 300-A is the Summary of Work-Related Injuries and Illnesses, and the OSHA 301 form is called the Injury and Illness Incident Report: On or about October 10, 2018, jobsite located at 3665 E Industrial Way, Riviera Beach, FL 33404, a log of all Work-Related Injuries and Illnesses (OSHA Form 300), and/or Summary of Work-Related Injuries and Illnesses, (OSHA Form 300-A), and/or the Injury and Illness Incident Report (OSHA Form 301) or equivalent forms were not kept by the establishment.
Citation ID 02002
Citaton Type Other
Standard Cited 19100303 G01 II
Issuance Date 2019-04-09
Abatement Due Date 2019-05-03
Current Penalty 744.0
Initial Penalty 744.0
Final Order 2019-05-02
Nr Instances 1
Nr Exposed 40
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: On or about October 10, 2018, jobsite located at 3665 E Industrial Way, Riviera Beach, FL 33404, the space in front of an electrical panels was not maintained and was obstructed by machinery blocking quick access to the electrical panels.
313105157 0418800 2009-09-22 3665 E. INDUSTRIAL WAY, RIVIERA BEACH, FL, 33404
Inspection Type Planned
Scope Records
Safety/Health Safety
Close Conference 2009-09-22
Emphasis N: SSTARG09
Case Closed 2009-09-30
310208244 0418800 2006-07-28 3665 E. INDUSTRIAL WAY, RIVIERA BEACH, FL, 33404
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2006-08-22
Emphasis N: AMPUTATE, S: AMPUTATIONS
Case Closed 2006-09-18

Related Activity

Type Complaint
Activity Nr 205223316
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100125 F03
Issuance Date 2006-08-25
Abatement Due Date 2006-08-30
Current Penalty 525.0
Initial Penalty 700.0
Nr Instances 1
Nr Exposed 32
Gravity 02
Citation ID 01002
Citaton Type Serious
Standard Cited 19100147 C04 I
Issuance Date 2006-08-25
Abatement Due Date 2006-10-13
Current Penalty 919.0
Initial Penalty 1225.0
Nr Instances 1
Nr Exposed 10
Gravity 05
Citation ID 01003
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2006-08-25
Abatement Due Date 2006-08-30
Current Penalty 525.0
Initial Penalty 700.0
Nr Instances 1
Nr Exposed 3
Gravity 02
Citation ID 01004A
Citaton Type Serious
Standard Cited 19100219 D01
Issuance Date 2006-08-25
Abatement Due Date 2006-08-30
Current Penalty 525.0
Initial Penalty 700.0
Nr Instances 3
Nr Exposed 7
Gravity 02
Citation ID 01004B
Citaton Type Serious
Standard Cited 19100219 E03 I
Issuance Date 2006-08-25
Abatement Due Date 2006-08-30
Nr Instances 3
Nr Exposed 7
Gravity 02
306183708 0418800 2003-10-09 3665 E. INDUSTRIAL WAY, RIVIERA BEACH, FL, 33404
Inspection Type Planned
Scope Complete
Safety/Health Health
Close Conference 2003-10-09
Emphasis N: SSTARG03, S: AMPUTATIONS
Case Closed 2003-10-29

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100133 A01
Issuance Date 2003-10-15
Abatement Due Date 2003-10-23
Current Penalty 394.0
Initial Penalty 525.0
Nr Instances 1
Nr Exposed 1
Gravity 01
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100151 C
Issuance Date 2003-10-15
Abatement Due Date 2003-11-10
Nr Instances 1
Nr Exposed 2
Gravity 01
Citation ID 01002
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2003-10-15
Abatement Due Date 2003-11-10
Current Penalty 525.0
Initial Penalty 700.0
Nr Instances 3
Nr Exposed 7
Gravity 02
18397307 0418800 1989-09-12 3665 E. INDUSTRIAL WAY, RIVIERA BEACH, FL, 33404
Inspection Type Complaint
Scope Complete
Safety/Health Health
Close Conference 1989-09-20
Case Closed 1989-10-26

Related Activity

Type Complaint
Activity Nr 72044456
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100094 D09 V
Issuance Date 1989-10-18
Abatement Due Date 1989-10-24
Current Penalty 200.0
Initial Penalty 200.0
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 05
Citation ID 02001A
Citaton Type Other
Standard Cited 19040005 B
Issuance Date 1989-10-18
Abatement Due Date 1989-10-24
Nr Instances 1
Nr Exposed 50
Gravity 01
Citation ID 02001B
Citaton Type Other
Standard Cited 19040005 C
Issuance Date 1989-10-18
Abatement Due Date 1989-10-24
Nr Instances 1
Nr Exposed 50
Gravity 01
Citation ID 02002A
Citaton Type Other
Standard Cited 19100107 B05 I
Issuance Date 1989-10-18
Abatement Due Date 1989-11-21
Nr Instances 1
Nr Exposed 1
Gravity 01
Citation ID 02002B
Citaton Type Other
Standard Cited 19100107 B05 IV
Issuance Date 1989-10-18
Abatement Due Date 1989-11-21
Nr Instances 1
Nr Exposed 1
Gravity 01
Citation ID 02002C
Citaton Type Other
Standard Cited 19100107 D03
Issuance Date 1989-10-18
Abatement Due Date 1989-11-21
Nr Instances 1
Nr Exposed 1
Gravity 01
Citation ID 02003A
Citaton Type Other
Standard Cited 19100134 B02
Issuance Date 1989-10-18
Abatement Due Date 1989-10-24
Nr Instances 1
Nr Exposed 1
Gravity 01
Citation ID 02003B
Citaton Type Other
Standard Cited 19100134 B11
Issuance Date 1989-10-18
Abatement Due Date 1989-10-24
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 01
Citation ID 02004A
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 1989-10-18
Abatement Due Date 1989-11-21
Nr Instances 1
Nr Exposed 50
Related Event Code (REC) Complaint
Gravity 01
Citation ID 02004B
Citaton Type Other
Standard Cited 19101200 H
Issuance Date 1989-10-18
Abatement Due Date 1989-11-21
Nr Instances 50
Nr Exposed 50
Related Event Code (REC) Complaint
Gravity 01

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
9112988803 2021-04-23 0455 PPS 3665 E Industrial Way 3665 E Industrial Way, Riviera Beach, FL, 33404-3401
Loan Status Date 2021-12-09
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 239007
Loan Approval Amount (current) 239007
Undisbursed Amount 0
Franchise Name -
Lender Location ID 44449
Servicing Lender Name PNC Bank, National Association
Servicing Lender Address 222 Delaware Ave, WILMINGTON, DE, 19801-1621
Rural or Urban Indicator U
Hubzone Y
LMI Y
Business Age Description Existing or more than 2 years old
Project Address Riviera Beach, PALM BEACH, FL, 33404-3401
Project Congressional District FL-21
Number of Employees 29
NAICS code 333515
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 44449
Originating Lender Name PNC Bank, National Association
Originating Lender Address WILMINGTON, DE
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 240401.21
Forgiveness Paid Date 2021-11-26

Date of last update: 03 Apr 2025

Sources: Florida Department of State