346567944
|
0419730
|
2023-03-15
|
14700 AEROSPACE PARKWAY, ORLANDO, FL, 32832
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-03-15
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2023-09-05
|
Related Activity
Type |
Referral |
Activity Nr |
2009880 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2023-07-18 |
Current Penalty |
10937.5 |
Initial Penalty |
15625.0 |
Final Order |
2023-08-29 |
Nr Instances |
1 |
Nr Exposed |
13 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. a) Jobsite: 14700 Aerospace Pkwy, Orlando, FL 32832, Warehouse router room: while employees serviced the vacuum extractor system, machine guarding was not installed on the CNC routing machine bit when in use, exposing employees to caught in between hazards, on or about March 13, 2023. No abatement certification or documentation required for this item. |
|
Citation ID |
01001B |
Citaton Type |
Other |
Standard Cited |
19100219 D01 |
Issuance Date |
2023-07-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-08-29 |
Nr Instances |
1 |
Nr Exposed |
13 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):(a) a) Jobsite: 14700 Aerospace Pkwy, Orlando, FL 32832, Warehouse router room: A guard was not installed on the AXYZ CNC Router Machine Model # 4016 Serial # 4708-4598 pully system, exposing employees to a pinch point hazard, on or about March 13, 2023. No abatement certification or documentation required for this item. |
|
|
345081939
|
0420600
|
2020-12-30
|
14700 AEROSPACE PARKWAY, ORLANDO, FL, 32832
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2020-12-30
|
Case Closed |
2021-09-29
|
Related Activity
Type |
Referral |
Activity Nr |
1708284 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2021-06-23 |
Abatement Due Date |
2021-09-27 |
Current Penalty |
4778.5 |
Initial Penalty |
9557.0 |
Final Order |
2021-07-16 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that, employees were exposed to fire hazards: At the paint booth, employees are using the metal forks of forklift to break the hardened Gelcoat material accumulated on the floor and pull it out of the paint booth. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100107 G02 |
Issuance Date |
2021-06-23 |
Abatement Due Date |
2021-09-27 |
Current Penalty |
4778.5 |
Initial Penalty |
9557.0 |
Final Order |
2021-07-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(g)(2):All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: At the paint booth, employees are exposed to fire hazards from accumulation of chemicals such as, but not limited to, Gelcoat on the floor. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100178 B12 |
Issuance Date |
2021-06-23 |
Abatement Due Date |
2021-09-27 |
Current Penalty |
4778.5 |
Initial Penalty |
9557.0 |
Final Order |
2021-07-16 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(b)(12):The atmosphere or location was not classified as to whether it was hazardous or nonhazardous prior to the consideration of industrial trucks being used therein and the type of industrial truck required was not provided as in paragraph (d) of this section for such location. At the paint booth, employees were exposed to fire hazards, in that, forklifts such as, but not limited to, propane fuel forklifts are used in areas where flammable conditions are likely to be present due to the accumulation of flammable materials. The employer failed to determine the type of industrial truck appropriate for the type of atmosphere or location. |
|
|
342103777
|
0420600
|
2017-02-14
|
14700 AEROSPACE PARKWAY, ORLANDO, FL, 32832
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2017-02-14
|
Case Closed |
2017-03-01
|
Related Activity
Type |
Complaint |
Activity Nr |
1180934 |
Safety |
Yes |
Health |
Yes |
|
|
339617227
|
0420600
|
2014-03-07
|
14700 AEROSPACE PARKWAY, ORLANDO, FL, 32832
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2014-03-26
|
Emphasis |
N: AMPUTATE, N: CHROME6, P: CHROME6
|
Case Closed |
2014-04-28
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100217 B06 I |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-05-05 |
Current Penalty |
2550.0 |
Initial Penalty |
4250.0 |
Final Order |
2014-04-28 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.217(b)(6)(i): Two hand trip(s) on mechanical power press(es) using full revolution clutches did not have the individual operator's hand controls protected against unintentional operation: a) Machine Shop - Chicago full revolution mechanical power press, model 406-D, serial number P-8252, had trips that were unprotected, on or about March 7, 2014. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100217 C03 VIII |
Issuance Date |
2014-04-09 |
Current Penalty |
2550.0 |
Initial Penalty |
4250.0 |
Final Order |
2014-04-28 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.217(c)(3)(viii): The two hand trip device did not protect the operator as specified in paragraph (c)(3)(i)(e) of this section: a) Machine Shop - Chicago full revolution mechanical power press, model 406-D, serial number P-8252, had trips that were 12 inches from the point of operation, on or about March 7, 2014. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100217 D09 I |
Issuance Date |
2014-04-09 |
Current Penalty |
1530.0 |
Initial Penalty |
2550.0 |
Final Order |
2014-04-28 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.217(d)(9)(i): The employer shall establish a diesetting procedure that will insure compliance with paragraph (c) of this section: a) Machine Shop - Chicago full revolution mechanical power press, model 406-D, serial number P-8252, had no procedure, on or about March 7, 2014. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100217 E01 I |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-05-05 |
Current Penalty |
2550.0 |
Initial Penalty |
4250.0 |
Final Order |
2014-04-28 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.217(e)(1)(i): A program of periodic and regular inspections of mechanical power press(es) was not established and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment: a) Machine Shop - Chicago full revolution mechanical power press, model 406-D, serial number P-8252, no inspections were conducted, on or about March 7, 2014. |
|
|