344203773
|
0419700
|
2019-08-02
|
6940 STUART AVENUE, JACKSONVILLE, FL, 32254
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-08-16
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2019-11-04
|
Related Activity
Type |
Referral |
Activity Nr |
1482550 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2019-08-21 |
Abatement Due Date |
2019-09-03 |
Current Penalty |
4958.0 |
Initial Penalty |
4958.0 |
Final Order |
2019-09-25 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, were not guarded: a. On August 2, 2019, in the slitter department, the RAS XL bending machine did not have an adequate guard in that the employee positioned the foot pedal within the light curtain, exposing himself to the point of operation. |
|
|
342028347
|
0419700
|
2017-01-17
|
6940 STUART AVENUE, JACKSONVILLE, FL, 32254
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-01-17
|
Case Closed |
2017-01-17
|
Related Activity
Type |
Inspection |
Activity Nr |
1180198 |
Safety |
Yes |
|
|
341801983
|
0419700
|
2016-09-28
|
6940 STUART AVENUE, JACKSONVILLE, FL, 32254
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-10-05
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2016-12-16
|
Related Activity
Type |
Inspection |
Activity Nr |
1180202 |
Safety |
Yes |
|
Type |
Referral |
Activity Nr |
1140566 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100217 C02 I A |
Issuance Date |
2016-11-02 |
Current Penalty |
12346.0 |
Initial Penalty |
12346.0 |
Final Order |
2016-11-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard: a. On or about September 27, 2016, the employer did not guard that prevented employees from reaching around it, while at the same time being able to operate the press, exposing employees to an amputation hazard. |
|
|
341028405
|
0419700
|
2015-10-23
|
6940 STUART AVE., JACKSONVILLE, FL, 32254
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-10-30
|
Emphasis |
N: AMPUTATE, L: FORKLIFT
|
Case Closed |
2016-05-20
|
Related Activity
Type |
Referral |
Activity Nr |
1031300 |
Safety |
Yes |
|
Type |
Referral |
Activity Nr |
1031375 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1131645 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2016-04-20 |
Current Penalty |
5390.0 |
Initial Penalty |
5390.0 |
Final Order |
2016-05-20 |
Nr Instances |
1 |
Nr Exposed |
52 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing hazards: a. On or about October 23, 2015, throughout the facility, employees operating forklifts were not wearing their seatbelts and were being exposed to crushing hazards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100023 A05 |
Issuance Date |
2016-04-20 |
Current Penalty |
5390.0 |
Initial Penalty |
5390.0 |
Final Order |
2016-05-20 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(a)(5): Every pit and floor opening was not adequately guarded by standard railing or any other effected means: a. On or about October 23, 2015, at the S-1 Slitter (Large pit area) employees looking down into the pit to visually check the height of the loop between the machines while the machine is running are being exposed to a 10 feet fall hazard. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19100212 A03 II |
Issuance Date |
2016-04-20 |
Current Penalty |
6468.0 |
Initial Penalty |
10780.0 |
Final Order |
2016-05-20 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury, was not guarded: a. On or about October 23, 2015, an employee working at the slitter was not protected from the point of operation while feeding in pieces of cardboard into the recoiler rollers. Florida Metal Products Inc. dba FLAMCO was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(3)(ii), which was contained in OSHA inspection number 954283, citation number 01, item number 001 and was affirmed as a final order on March 17, 2014, with respect to a workplace located at 6940 Stuart Ave, Jacksonville, FL 32236. |
|
|
339571630
|
0419700
|
2014-02-03
|
6940 STUART AVE, JACKSONVILLE, FL, 32236
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2014-02-07
|
Emphasis |
L: HINOISE
|
Case Closed |
2014-05-30
|
Related Activity
Type |
Referral |
Activity Nr |
870006 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
954283 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100095 C01 |
Issuance Date |
2014-02-26 |
Abatement Due Date |
2014-05-07 |
Current Penalty |
0.0 |
Initial Penalty |
4590.0 |
Final Order |
2014-03-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: a. An employee, assembling metal ventilation parts, was exposed to a noise dose of 105.7%, or an equivalent dBA (decibels A scale) of 90.4 dBA, which is capable of causing hearing loss. The noise sampling was conducted for 375 minutes during one work shift on February 3, 2014. The employer did not provide an effective hearing conservation program, in that all employees were not provided a baseline audiogram within 6 months of their first exposure, nor were they informed of the purpose or requirements for wearing hearing protectors, the advantage, disadvantaged, and attenuation of various types, or instructions on the selection, fitting, use, and care of hearing protectors. |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19101200 F05 I |
Issuance Date |
2014-02-26 |
Abatement Due Date |
2014-03-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-03-17 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: a. On or about February 3, 2014, the company had three containers, one approximately 5-gallon and two 50 ml secondary containers, each containing the chemical, 2020SS Caulk Seam Seal Brushon, located in the assembling area that did not have the required labels showing the identity of the hazardous chemical contained therein. |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19101200 F05 II |
Issuance Date |
2014-02-26 |
Abatement Due Date |
2014-03-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-03-17 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: a. On or about February 3, 2014, the company had three containers, one approximately 5-gallon and two 50 ml secondary containers, each containing the chemical, 2020SS Caulk Seam Seal Brushon, located in the assembling area that did not have the required labels showing the appropriate hazard warnings. |
|
|
339542839
|
0419700
|
2014-01-09
|
6940 STUART AVE, JACKSONVILLE, FL, 32236
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-01-13
|
Emphasis |
L: FORKLIFT, N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2014-03-26
|
Related Activity
Type |
Inspection |
Activity Nr |
957163 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100212 A03 II |
Issuance Date |
2014-02-26 |
Current Penalty |
0.0 |
Initial Penalty |
3825.0 |
Final Order |
2014-03-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury, was not guarded: a. On or about January 10, 2014, an employee, working at the Forisiner Slitter, was exposed to amputation hazards because they were not protected from cutter blades while collecting and stacking blanks. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100147 C06 I |
Issuance Date |
2014-02-26 |
Abatement Due Date |
2014-03-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-03-17 |
Nr Instances |
3 |
Nr Exposed |
36 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a. On or about January 10, 2014, the employer had not performed an inspection on energy control procedures annually for machines, including but not limited to slitters, rivets, presses. |
|
|
315484519
|
0419700
|
2012-02-14
|
6940 STUART AVE, JACKSONVILLE, FL, 32254
|
|
Inspection Type |
Planned
|
Scope |
NoInspection
|
Safety/Health |
Health
|
Close Conference |
2012-02-14
|
Emphasis |
S: NOISE, L: HINOISE
|
Case Closed |
2012-02-15
|
|
310029053
|
0419700
|
2006-12-06
|
6940 STUART AVE, JACKSONVILLE, FL, 32254
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2006-12-07
|
Emphasis |
S: AMPUTATIONS
|
Case Closed |
2006-12-15
|
Related Activity
Type |
Complaint |
Activity Nr |
206141525 |
Safety |
Yes |
Health |
Yes |
|
|
306749425
|
0419700
|
2004-02-27
|
6940 STUART AVE, JACKSONVILLE, FL, 32254
|
|
Inspection Type |
Planned
|
Scope |
NoInspection
|
Safety/Health |
Safety
|
Emphasis |
N: AMPUTATE, S: AMPUTATIONS
|
Case Closed |
2004-03-02
|
|
100340967
|
0419700
|
1986-02-19
|
6830 HIGHWAY AVE., JACKSONVILLE, FL, 32205
|
|
Inspection Type |
Planned
|
Scope |
Records
|
Safety/Health |
Safety
|
Close Conference |
1986-02-20
|
Case Closed |
1986-02-20
|
|
13693429
|
0419700
|
1979-07-19
|
2670 PHYILIS ST, Jacksonville, FL, 32205
|
|
Inspection Type |
FollowUp |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
1979-07-19 |
Case Closed |
1984-03-10 |
|
13708508
|
0419700
|
1978-07-13
|
2670 PHYLLIS STREET, Jacksonville, FL, 32205
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
1978-07-14 |
Case Closed |
1980-09-29 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100217 C01 I |
Issuance Date |
1978-07-25 |
Abatement Due Date |
1978-08-24 |
Current Penalty |
250.0 |
Initial Penalty |
250.0 |
Contest Date |
1978-08-15 |
Nr Instances |
1 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
1978-07-25 |
Abatement Due Date |
1979-04-23 |
Current Penalty |
250.0 |
Initial Penalty |
250.0 |
Contest Date |
1978-08-15 |
Nr Instances |
3 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100219 E03 I |
Issuance Date |
1978-07-25 |
Abatement Due Date |
1978-08-24 |
Current Penalty |
250.0 |
Initial Penalty |
250.0 |
Contest Date |
1978-08-15 |
Nr Instances |
1 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100106 E06 II |
Issuance Date |
1978-07-25 |
Abatement Due Date |
1978-08-24 |
Nr Instances |
1 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100178 P01 |
Issuance Date |
1978-07-25 |
Abatement Due Date |
1978-08-24 |
Current Penalty |
50.0 |
Initial Penalty |
50.0 |
Contest Date |
1978-08-15 |
Nr Instances |
2 |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100212 A05 |
Issuance Date |
1978-07-25 |
Abatement Due Date |
1978-08-24 |
Nr Instances |
1 |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19100215 A04 |
Issuance Date |
1978-07-25 |
Abatement Due Date |
1978-08-24 |
Nr Instances |
1 |
|
Citation ID |
02005 |
Citaton Type |
Other |
Standard Cited |
19100217 B04 I |
Issuance Date |
1978-07-25 |
Abatement Due Date |
1978-08-24 |
Nr Instances |
2 |
|
Citation ID |
02006 |
Citaton Type |
Other |
Standard Cited |
19100217 E01 I |
Issuance Date |
1978-07-25 |
Abatement Due Date |
1978-08-24 |
Nr Instances |
4 |
|
Citation ID |
02007 |
Citaton Type |
Other |
Standard Cited |
19100252 A02 IVC |
Issuance Date |
1978-07-25 |
Abatement Due Date |
1978-08-24 |
Nr Instances |
1 |
|
Citation ID |
02008 |
Citaton Type |
Other |
Standard Cited |
19100309 A 011022 |
Issuance Date |
1978-07-25 |
Abatement Due Date |
1978-08-24 |
Nr Instances |
1 |
|
Citation ID |
02009 |
Citaton Type |
Other |
Standard Cited |
19100309 B 037015 |
Issuance Date |
1978-07-25 |
Abatement Due Date |
1978-08-24 |
Current Penalty |
50.0 |
Initial Penalty |
50.0 |
Contest Date |
1978-08-15 |
Nr Instances |
1 |
|
|
13722749
|
0419700
|
1977-01-18
|
2670 PHYLLIS ST, Jacksonville, FL, 32204
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
1977-01-18 |
Case Closed |
1977-02-15 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100022 D01 |
Issuance Date |
1977-01-25 |
Abatement Due Date |
1977-03-01 |
Nr Instances |
1 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100023 C01 |
Issuance Date |
1977-01-25 |
Abatement Due Date |
1977-03-01 |
Nr Instances |
1 |
|
|
13632658
|
0419700
|
1975-04-17
|
2670 PHYLLIS ST, Jacksonville, FL, 32204
|
|
Inspection Type |
Planned |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
1975-04-17 |
Case Closed |
1975-05-13 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100215 B09 |
Issuance Date |
1975-04-25 |
Abatement Due Date |
1975-05-14 |
Nr Instances |
1 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100178 N04 |
Issuance Date |
1975-04-25 |
Abatement Due Date |
1975-05-14 |
Nr Instances |
1 |
|
Citation ID |
01003A |
Citaton Type |
Other |
Standard Cited |
19100134 B05 |
Issuance Date |
1975-04-25 |
Abatement Due Date |
1975-04-29 |
Nr Instances |
1 |
|
Citation ID |
01003B |
Citaton Type |
Other |
Standard Cited |
19100134 B06 |
Issuance Date |
1975-04-25 |
Abatement Due Date |
1975-04-29 |
Nr Instances |
1 |
|
|